Diagnosis and redesign of power plants using combined Pinch and Exergy Analysis
This paper applies the combined Pinch and Exergy Approach in analysing the operation and design of a typical steam power plant. This work quantifies the total, avoidable an unavoidable exergy loss for the equipment, which means, the potential for equipment improvement. On the other hand, the analysis of cross pinch heat transfer in the process identifies additional losses of energy due to the inefficient design of the heat recovery system.
Year of publication: |
2014
|
---|---|
Authors: | Arriola-Medellín, Alejandro ; Manzanares-Papayanopoulos, Emilio ; Romo-Millares, César |
Published in: |
Energy. - Elsevier, ISSN 0360-5442. - Vol. 72.2014, C, p. 643-651
|
Publisher: |
Elsevier |
Subject: | Pinch Technology | Exergy Analysis | Power plants | Energy reduction potential |