Passive cooling of building using multi air gaps
In this paper the thermal performance of an air space in an inclined roof and the optimum number of air spaces are discussed. One face of the roof is exposed to solar radiation and ambient air and the other is in contact with room air at a constant temperature. It is found that, for the desired thermal performance, the roof should always be horizontal. It is also inferred that dividing an air gap into a number of gaps reduces the heat flux coming into the room. At most, one may effectively use only four air gaps. The effect of using reflecting sheets in the air spaces has also been investigated. To achieve the best thermal load levelling, the outer concrete leaf should be of least thickness.
Year of publication: |
1981
|
---|---|
Authors: | Singh, U. ; Kumar, A. ; Srivastava, A. ; Tiwari, G. N. |
Published in: |
Applied Energy. - Elsevier, ISSN 0306-2619. - Vol. 9.1981, 1, p. 33-48
|
Publisher: |
Elsevier |
Saved in:
Online Resource
Saved in favorites
Similar items by person
-
Thermal design of a roof as an inexpensive solar collector/storage system
Kumar, A., (1981)
-
Sodha, M.S., (1981)
-
Periodic theory of an open roof pond
Sodha, M.S., (1980)
- More ...