Performance of alternative refrigerants for residential air-conditioning applications
In this study, performances of two pure hydrocarbons and seven mixtures composed of propylene, propane, HFC152a, and dimethylether were measured to substitute for HCFC22 in residential air-conditioners and heat pumps. Thermodynamic cycle analysis was carried out to determine the optimum compositions before testing and actual tests were performed in a breadboard-type laboratory heat pump/air-conditioner at the evaporation and condensation temperatures of 7 and 45 °C, respectively. Test results show that the coefficient of performance of these mixtures is up to 5.7% higher than that of HCFC22. While propane showed a 11.5% reduction in capacity, most of the fluids had a similar capacity to that of HCFC22. For these fluids, compressor-discharge temperatures were reduced by 11-17 °C. For all fluids tested, the amount of charge was reduced by up to 55% as compared to HCFC22. Overall, these fluids provide good performances with reasonable energy-savings without any environmental problem and thus can be used as long-term alternatives for residential air-conditioning and heat-pumping applications.
Year of publication: |
2007
|
---|---|
Authors: | Park, Ki-Jung ; Seo, Taebeom ; Jung, Dongsoo |
Published in: |
Applied Energy. - Elsevier, ISSN 0306-2619. - Vol. 84.2007, 10, p. 985-991
|
Publisher: |
Elsevier |
Keywords: | Natural refrigerants Hydrocarbons Refrigerant mixtures Residential air-conditioners Heat pumps |
Saved in:
Online Resource
Saved in favorites
Similar items by person
-
Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps
Park, Ki-Jung, (2008)
-
Performance of heat pumps charged with R170/R290 mixture
Park, Ki-Jung, (2009)
-
Park, Ki-Jung, (2007)