Preparation and certification of a new batch of 243Am spike IRMM-049e : certified reference material for the 243Am and n(241Am)/n(243Am) isotope amount ratio : certification report
This report describes the preparation and certification of IRMM-0243, a 243Am spike reference material. It is certified for the amount content of 243Am and the n(241Am)/n(243Am) isotope amount ratio. Furthermore, the material is certified for the amount contents of 241Am and total Am, the mass fractions of 243Am, 241Am and total Am, the isotope amount and mass fractions (e.g. isotopic composition) and the molar mass of Am. The material was produced in compliance with ISO/IEC 17034:2016 [1] and certified in accordance with ISO Guide 35:2006 [2]. The material was prepared by dilution of an americium starting solution in nitric acid and dispensing of the solution into glass ampoules. In total 587 units were produced. Between-unit homogeneity was quantified and stability during dispatch and storage were assessed in accordance with ISO Guide 35:2006 [2]. The characterisation of the amount content of 243Am was performed by Isotope Dilution Mass Spectrometry (IDMS) using a 241Am spike, produced from highly enriched 241Pu material. The n(241Am)/n(243Am) isotope amount ratio was measured by Thermal Ionisation Mass Spectrometry (TIMS). The certified values were verified by alpha particle spectrometry, alpha particle counting at a defined solid angle (DSA) and high-resolution gamma-ray spectrometry as independent verification methods. The uncertainties of the certified values were estimated in compliance with the Guide to the Expression of Uncertainty in Measurement (GUM) [3] and include uncertainties related to possible inhomogeneity, instability and characterisation. The indicative value for the n(242mAm)/n(243Am) isotope amount ratio and its uncertainty were derived from the inter-laboratory comparison (ILC) organised by CEA/CETAMA using IRMM-0243 as the test sample. The main purpose of this material is for use as a spike isotopic reference material for the quantification of americium by IDMS in unknown samples. A unit of IRMM-0243 consists of a glass ampoule with a screw cap containing about 3.5 mL nitric acid solution (c = 1 mol/L) with an americium mass fraction of about 1.5 μg/g solution. The material is a true solution; therefore there is no recommended minimum sample intake to be taken into account.
Year of publication: |
2017
|
---|---|
Other Persons: | Jakopič, R. (contributor) ; Fankhauser, A. (contributor) ; Aregbe, Y. (contributor) ; Crozet, M. (contributor) ; Maillard, C. (contributor) ; Richter, S. (contributor) ; Rivier, C. (contributor) ; Roudil, D. (contributor) ; Altzitzoglou, T. (contributor) ; Pommé, S. (contributor) ; Marouli, N. (contributor) ; Tzika, F. (contributor) |
Institutions: | European Commission / Joint Research Centre (issuing body) |
Publisher: |
Luxembourg : Publications Office |
Saved in:
Extent: | 1 Online-Ressource (72 p.) Illustrationen (farbig) |
---|---|
Type of publication: | Book / Working Paper |
Language: | English |
Notes: | Bibl. : p. 28-29 |
ISBN: | 978-92-79-72281-3 |
Other identifiers: | 10.2760/40283 [DOI] |
Source: | ECONIS - Online Catalogue of the ZBW |
Persistent link: https://www.econbiz.de/10015287070
Saved in favorites
Similar items by person
-
Jakopič, R., (2018)
-
Buják, R., (2017)
-
Venchiarutti, C., (2017)
- More ...