Showing 1 - 10 of 90
explored. This tool allows the predetermination of variables such as the overall heat transfer coefficient, effectiveness …
Persistent link: https://www.econbiz.de/10011077735
effectiveness according to NTU. …
Persistent link: https://www.econbiz.de/10011117589
exchanger, on the overall thermal resistance of the loops. The values of the effectiveness of the heat pipe heat exchanger are … shown to vary with the air velocity as expected but the results also allow the prediction of effectiveness variation with …
Persistent link: https://www.econbiz.de/10010807249
In this paper, exergy transfer effectiveness is defined to describe the performance of heat exchangers operating above … effectiveness of heat exchangers. Furthermore, the results of exergy transfer effectiveness with a finite pressure drop are compared … applied. The detailed comparisons of the exergy transfer effectiveness with heat transfer effectiveness are also performed for …
Persistent link: https://www.econbiz.de/10010808678
cooler and a sensible heat exchanger (SHE) in series, was made, and the effectiveness data of the pilot unit were acquired …. The test result shows that over 40% effectiveness can be acquired even in hot and humid climates by using the Dry Coil IEC … effectiveness of the Dry Coil IEC was derived as a function of seven independent variables highly influencing the performance of the …
Persistent link: https://www.econbiz.de/10010810224
In the 20th Century many buildings became totally dependent on fossil fuel energy to make them habitable. Recent legislation and building regulations, however, ensure that designers are contracted to aim for zero carbon sustainability or buildings which function with much lower levels of fossil...
Persistent link: https://www.econbiz.de/10010810262
This paper presents an innovative correlation associating the effectiveness (ε) of the cooling tower with its number of …
Persistent link: https://www.econbiz.de/10011053872
The present study is concerned with the exergoeconomic performance analysis of a storage-type electrical water heater, being subjected to two volumes of hot water removals at 5 L/min; the first one immediately after the heating of water in the tank, and the second, after some time has been...
Persistent link: https://www.econbiz.de/10011264418
performance features such as high efficiency and output power. In the present study, three the-state-of-the-art multi … features of a thermoelectric generator for improved efficiency and output power while incorporating different operating … performance. Increasing shape factor (S ≤ 0.5) first increases thermal efficiency to reach its maximum (∼17%), and furthermore, an …
Persistent link: https://www.econbiz.de/10011077666
depends on incorporating alternative water sources and improving water-energy use efficiency. This paper assesses water and …
Persistent link: https://www.econbiz.de/10011077720