Showing 1 - 2 of 2
The performance of an advanced triple-pressure level (TPL) single-stage absorption cycle with refrigerant R125 and various organic absorbents were studied. In the developed TPL cycle, a jet ejector of a special design is added at the absorber inlet. The device serves two major functions: it...
Persistent link: https://www.econbiz.de/10010811264
An experimental study of flow boiling of binary organic solution was conducted in a horizontal tube. An organic mixture of miscible fluids, chlorodifluoromethane (R22)–dimethylacetamide (DMAC) was circulated through the experimental system. The influence of the heat source, flow rate,...