This work deals with a diagnosis of cathode flooding and membrane drying associated with a low frequency ripple current of a polymer electrolyte membrane fuel cell (PEMFC) based on impedance measurement on 12 single cells using electrochemical impedance spectroscopy (EIS). Average values of the...