Showing 1 - 2 of 2
The experimental part of the study of the reverse cycle defrosting performance on a four-circuit outdoor coil unit in an experimental 6.5kW heating capacity residential ASHP has been reported in Part I of a two-part series. The experimental results indicated that downwards flowing of the melted...
Persistent link: https://www.econbiz.de/10010576276
Reverse cycle defrosting is the most widely used standard defrosting method for air source heat pump (ASHP) units. It was suggested in previous experimental studies that during reverse cycle defrosting, downwards flowing of the melted frost due to gravity over a vertically installed...
Persistent link: https://www.econbiz.de/10011076331