Showing 1 - 10 of 2,021
A new generation of highly efficient absorbers for direct air-cooled LiBr/H2O absorption machines is presented and … air-cooled single–double-effect absorption machine. Simulation outcomes of that specific absorber were compared with some … experimental results obtained by using the aforementioned absorption machine as testing facility to validate the model. A good …
Persistent link: https://www.econbiz.de/10011040499
In this paper a review of solar cooling and refrigeration technologies is presented. A discussion on the main reasons why these technologies are not presently economically feasible is carried out. and two installations in Mexico are analysed.
Persistent link: https://www.econbiz.de/10010804104
This work presents a comparative study of the performance of absorption cooling systems with internal storage and with … external storage. A full dynamic simulation model including the solar collector field, the absorption heat pump system and the … absorption pump and external storage in a water tank. Many batteries of simulations have been done to evaluate the performance of …
Persistent link: https://www.econbiz.de/10011044428
environment and the electricity distribution system. Solar absorption cooling arises as an interesting alternative, which at the … still persist in solar absorption systems, which could make them loose their market potential for the benefit of other solar …
Persistent link: https://www.econbiz.de/10011044910
paper investigates and compares the performance of two types of solar cooling: solar absorption cooling system and solar … in Gladstone and Rockhampton sites respectively, while the absorption system will achieve a 0.81 and 0.75 of solar …
Persistent link: https://www.econbiz.de/10010665970
The slow diffusion of an absorbate molecule into an absorbent often makes the absorption process a rate-limiting step … in many applications. In cases involving an absorbate with a high heat of phase change, such as water absorption into a … LiBr (lithium bromide) solution, the absorption rate is further slowed due to significant heating of the absorbent …
Persistent link: https://www.econbiz.de/10010810537
A system often discussed in the available literature is that of a single-effect lithium bromide chiller and a fixed solar collector. An analysis of published articles showed that prototype trough and evacuated flat plate collectors can efficiently produce liquids hot enough to drive...
Persistent link: https://www.econbiz.de/10011043820
A variable effect absorption refrigeration cycle is proposed which can obtain a rising COP (Coefficient of Performance …) versus the rising generation temperature. This novel cycle could be applied for solar absorption cooling efficiently. In this … paper, a 50 kw variable effect (also named as 1.n effect) absorption chiller using LiBr-water as working fluid was designed …
Persistent link: https://www.econbiz.de/10011077724
This paper reports the experimental results of a single effect absorption cooling system of 3 kW of nominal cooling … temperatures to remove the heat produced during the condensation and absorption varied between 18 °C and 36 °C. The results showed …
Persistent link: https://www.econbiz.de/10011117579
On the basis of the Number of Transfer Units (NTU) method a functional relation between electric power for fans/pumps and effectiveness in dry coolers and wet cooling towers is developed. Based on this relation, a graphical presentation method of monitoring and simulation data of heat rejection...
Persistent link: https://www.econbiz.de/10011127938