Showing 1 - 10 of 46
This paper presents the effects of spectral irradiance distribution on the performance of polycrystalline (p-Si) and amorphous silicon (a-Si) photovoltaic (PV) modules under Thai climatic conditions. The annual outdoor solar spectrum measurements bouncing on the PV modules installed at Energy...
Persistent link: https://www.econbiz.de/10010807000
This work is aimed at verifying that analytical modelling approaches may provide an estimation of the outdoor performance of TF (thin film) PV (photovoltaic) technologies in inland sites with sunny climates with adequate accuracy for engineering purposes. Osterwald's and constant fill factor...
Persistent link: https://www.econbiz.de/10011054400
Three different, commercially available photovoltaic modules have been monitored outdoors in the town of Grimstad, Norway. The present paper describes the experimental setup that was implemented, in particular details of the low-cost electronic loads. Results compare measured performance with...
Persistent link: https://www.econbiz.de/10011044045
payback periods for the PV system for these houses are 7 and 7.4 years respectively. We concluded that integrated PV (BIPV …
Persistent link: https://www.econbiz.de/10011205760
The presence of an air gap between a photovoltaic (PV) module and roof facilitates ventilation cooling under the device and consequently reduces cell temperature and improves its performance. In case of rack-mounted PV installation, the Nominal Operating Cell Temperature (NOCT) method could be...
Persistent link: https://www.econbiz.de/10010805039
The importance of solar cell/module operating temperature for the electrical performance of silicon-based photovoltaic installations is briefly discussed. Suitable tabulations are given for most of the explicit and implicit correlations found in the literature which link this temperature with...
Persistent link: https://www.econbiz.de/10010805619
. The main electricity generator is the 142.5kWp grid-connected BIPV system on the roof of the building. This paper presents … the first performance assessment of the BIPV system over 18 months of operation following the guidelines of the IEC …
Persistent link: https://www.econbiz.de/10010805642
The photovoltaic (PV) cells suffer efficiency drop as their operating temperature increases especially under high insolation levels and cooling is beneficial. Air-cooling, either by forced or natural flow, presents a non-expensive and simple method of PV cooling and the solar preheated air could...
Persistent link: https://www.econbiz.de/10010805715
A residential-scale building integrated photovoltaic (BiPV) cogeneration system has been thermographically investigated … combined heat and power system is based on existing BiPV roofing technology with the addition of a modular heat recovery unit …
Persistent link: https://www.econbiz.de/10010806266
test conditions. Economically, this study shows that building integrated photovoltaic (BIPV) systems are not viable in GCC … power plants. When these considerations are taken into account then BIPV should become a feasible technology in GCC …
Persistent link: https://www.econbiz.de/10010806285