An experimental study of pressure drop and friction factor for laminar and transition opposing mixed convection in entrance region of rectangular duct
Year of publication: |
2011
|
---|---|
Authors: | Chong, DaoTong ; Liu, JiPing ; Yan, JunJie |
Published in: |
Energy conversion and management : ECM. - Oxford [u.a.] : Pergamon Press, ISSN 0196-8904, ZDB-ID 7576912. - Vol. 52.2011, 5, p. 2272-2282
|
Saved in:
Saved in favorites
Similar items by person
-
Experimental and numerical analysis of supersonic air ejector
Chong, Daotong, (2014)
-
Thermodynamic analysis of pre-drying methods for pre-dried lignite-fired power plant
Liu, Ming, (2013)
-
Han, Xiaoqu, (2014)