Management of vacuum leak-detection processes, standards, and calibration
Vacuum leak detection requires integrated management action to ensure the successful production of apparatus having required leak tightness. Implementation of properly planned, scheduled, and engineering procedures and test arrangements are an absolute necessity to prevent unexpected, impractical, technically inadequate, or unnecessarily costly incidents in leak-testing operations. The use of standard procedures, leak standards appropriate to the task, and accurate calibration systems or devices is necessary to validate the integrity of any leak-test procedure. In this paper, the need for implementing these practices is discussed using case histories of typical examples of large complex vacuum systems. Aggressive management practices are of primary importance throughout a project's life cycle to ensure the lowest cost; this includes successful leak testing of components. It should be noted that the opinions and conclusions expressed in this paper are those of the author and are not those of the Los Alamos National Laboratory or the Department of Energy.
Year of publication: |
2009-04-02
|
---|---|
Authors: | Wilson, N.G. |
Subject: | engineering | LEAK TESTING | CALIBRATION | CALIBRATION STANDARDS | VACUUM SYSTEMS | STANDARDS | TESTING |