Heat exchanger: Optimal separation for vertical rectangular fins protruding from a vertical rectangular base
An experimental investigation of the steady-state rates of heat transfer from an array of vertical rectangular 3 mm thick fins, extending 60 mm perpendicularly out of a 250 mm high vertical rectangular base, is reported. For base temperatures between room temperature (~ 15°C) and 100°C, the optimal separation of the parallel fins, corresponding to the maximum rate of heat loss, is 10 ± 1 mm.
Year of publication: |
1985
|
---|---|
Authors: | Leung, C.W. ; Probert, S.D. ; Shilston, M.J. |
Published in: |
Applied Energy. - Elsevier, ISSN 0306-2619. - Vol. 19.1985, 2, p. 77-85
|
Publisher: |
Elsevier |